638 research outputs found

    Nutritional Composition of Stevia rebaudiana Bertoni Leaf: Effect of Drying Method

    Get PDF
    Purpose: To determine the effect of three methods of drying, viz, sun, oven and microwave, on Steviarebaudiana Bertoni leaf’s nutritional composition.Methods: Fresh Stevia rebaudian bertoni leaves were dried separately by sun, oven and microwave.The chemical composition was determined by Association of Official Agricultural Chemists (AOAC)method. Tannin content was measured by titrimetric method while heavy metals were analyzed byatomic absorption spectrometry.Results: The following data were obtained for the plant when the three drying methods were employed:moisture content, 4.45 – 10.73 %; ash, 4.65 – 12.06 %; protein, 12.44 – 13.68 %; fat, 4.18 – 6.13 %;total dietary fiber, 4.35 – 5.26 % and total carbohydrates, 63.10 – 73.99 %. The pH value was 5.96, 5.95and 6.24 for sun, oven and microwave drying, respectively. Total energy of the plant material was in therange 362.3 – 384.2 kcal/100 g while tannin content was in the range 5.43 – 5.91 %. Moreover,reducing sugar was 4.5, 4.8 and 5.3 %, respectively, for sun, oven and microwave drying. Heavy metalscontent varied in stevia leaves, with lead was detected in high concentration in sun-, oven- andmicrowave–dried materials with values of 4.77, 0.14 and 2.16 ìg/g, respectively, while thecorresponding values for cadmium were 0.49, 0.44 and 0.33 ìg/g, Arsenic level was 0.30, 0.09 and 0.10ìg/g for sun, oven and microwave drying, respectively. Mercury level was the same (0.1 ìg/g)irrespective of the drying method.Conclusion: The results obtained indicate that Stevia leaves is a good source of carbohydrate andother nutrients and hence a substitute for sugar in processed drinks. Furthermore, drying reducesnutritional values with the exception to fiber content.Keywords: Stevia rebaudiana Bertoni , Nutritional composition, Protein, Heavy metals, Drying, Totalenerg

    Extract of Perilla frutescens inhibits tumor proliferation of HCC via PI3K/AKT signal pathway

    Get PDF
    In this study, isoegomaketone(IK) was isolated from Perilla frutescens(L.), a Chinese herbal. The effects of IK were examined by cell viability assay, colony formation assay, xenograft tumor assay and western blotting in HCC cells. Wefound that IK inhibited cell viability, and its administration decreased tumor volume and weight profoundly. The presence of IK(10nmol/l) produced a dramatic decrease of pAkt, while total Akt level was not affected. The data suggested that IK from perilla suppressed HCC tumor growth via blocking PI3K/Akt signaling pathway

    Optimization of the design of ducted-fan hovering micro air vehicles using finite element simulation and orthogonal design

    Get PDF
    The structural design and flight stability characteristics of micro air vehicles have received much attention due to its low Reynolds number. Compared with fixed-wing aircraft, hovering ducted-fan micro air vehicles with vertical takeoff and landing and hovering capabilities have promising prospect. In this article, a flexible membrane and inflatable structure has been used as the aerodynamic shape of an aircraft model. Its advantages have been analyzed and verified by fluid-structure interaction based on finite element method. The flight stability of hovering micro air vehicles has also been investigated based on the theory of motion of structure. In order to improve the flight stability of the designed hovering micro air vehicle model, the effects of geometrical parameters and materials have been analyzed through an orthogonal experimental design. Based on the optimized results, the aircraft prototype has been manufactured for experimental test. The elastic deformation produced on its flexible membrane structure is obtained by stroboscopic stereo imaging method and a purpose-built experimental environment. The numerical simulation results indicated that the thickness of membrane and material of vertical duct have significant effects on the micro air vehicle flight stability and disturbance resistance ability. The results have confirmed that the flexible aerodynamic mechanisms produced by the aeroelastic deformation of spherical membrane can enhance the micro air vehicle stability.This work was financially supported by Support Program of National Ministry of Education of China (No. 625010110), National Natural Science Foundation of China (No. 61179043), and Specialized Research Fund for the Doctoral Program (SRFDP) of Higher Education (No. 20070056085)

    May Measurement Month (MMM) 2017: an analysis of blood pressure screening results in Bangladesh-South Asia

    Get PDF
    Elevated blood pressure (BP) is a growing burden worldwide, leading to over 10 million deaths each year. Based on the findings of the non-communicable disease Risk Factors Survey Bangladesh 2010, the prevalence of hypertension in adults 25 years or older in Bangladesh is 20.1%. The Bangladesh Demographic Health Survey, 2011 showed that approximately 50% of those affected are unaware of their hypertensive condition. The May Measurement Month 2017 (MMM17) is a global initiative of the International Society of Hypertension (ISH) aimed at raising awareness of high BP. We participated in MMM17 to raise awareness of hypertension screening and identify those with elevated BP who were unaware, and those on treatment with still uncontrolled hypertension. Following the standard protocol designed by the ISH, we participated in MMM17, an opportunistic cross-sectional survey of volunteers aged ≥18. It was carried out in May 2017. BP measurement, the definition of hypertension and statistical analysis followed the standard MMM protocol. Data were collected from 35 screening sites in 33 districts in Bangladesh. Personnel from several government and non-government organizations volunteered in this huge event. A total of 11 418 individuals were screened during MMM17, of which 5401 (47.3%) were found to have hypertension. Of 8365 individuals not receiving anti-hypertensive medication, 2348 (28.1%) were hypertensive. Of 3053 individuals receiving anti-hypertensive medication, 1594 (52.2%) had uncontrolled BP. MMM17 was the largest BP screening campaign undertaken in Bangladesh. This study suggests that opportunistic screening can identify significant numbers of people with raised BP. A periodic public health programme at a national level needs to be initiated to increase hypertension detection and control rate and thus for the prevention of cardiovascular diseases

    Pyrite oxidation inhibition by a cross-linked lipid coating

    Get PDF
    The effect of a diacetylene-containing phospholipid on the oxidation of pyrite, FeS(2), was investigated. Earlier work reported by our research group showed that the adsorption of l,2-bis(10,12-tricosadiynoyl)-sn-glycero-3-phosphocholine on pyrite suppressed the extent of its oxidation by about 75% over a specific time period. Results presented here show that the pre-exposure to UV radiation of this lipid after sorption onto pyrite results in a 90% suppression. Attenuated total reflection (ATR) Fourier transform infra-red spectroscopy (FTIR) suggests that the UV irradiation of the lipid does not result in degradation of the adsorbed layer. It is believed that the UV exposure results in the cross-linking and polymerization of the adsorbed phospholipid into a relatively impermeable barrier that separates the pyrite from the aqueous phase. The results of this study might have implications for the protection of pyrite from oxidation in the environment

    Study of e+eppˉe^+e^- \rightarrow p\bar{p} in the vicinity of ψ(3770)\psi(3770)

    Full text link
    Using 2917 pb1\rm{pb}^{-1} of data accumulated at 3.773~GeV\rm{GeV}, 44.5~pb1\rm{pb}^{-1} of data accumulated at 3.65~GeV\rm{GeV} and data accumulated during a ψ(3770)\psi(3770) line-shape scan with the BESIII detector, the reaction e+eppˉe^+e^-\rightarrow p\bar{p} is studied considering a possible interference between resonant and continuum amplitudes. The cross section of e+eψ(3770)ppˉe^+e^-\rightarrow\psi(3770)\rightarrow p\bar{p}, σ(e+eψ(3770)ppˉ)\sigma(e^+e^-\rightarrow\psi(3770)\rightarrow p\bar{p}), is found to have two solutions, determined to be (0.059±0.032±0.0120.059\pm0.032\pm0.012) pb with the phase angle ϕ=(255.8±37.9±4.8)\phi = (255.8\pm37.9\pm4.8)^\circ (<<0.11 pb at the 90% confidence level), or σ(e+eψ(3770)ppˉ)=(2.57±0.12±0.12\sigma(e^+e^-\rightarrow\psi(3770)\rightarrow p\bar{p}) = (2.57\pm0.12\pm0.12) pb with ϕ=(266.9±6.1±0.9)\phi = (266.9\pm6.1\pm0.9)^\circ both of which agree with a destructive interference. Using the obtained cross section of ψ(3770)ppˉ\psi(3770)\rightarrow p\bar{p}, the cross section of ppˉψ(3770)p\bar{p}\rightarrow \psi(3770), which is useful information for the future PANDA experiment, is estimated to be either (9.8±5.79.8\pm5.7) nb (<17.2<17.2 nb at 90% C.L.) or (425.6±42.9)(425.6\pm42.9) nb

    Increasing source to image distance for AP pelvis imaging – impact on radiation dose and image quality

    Get PDF
    Aim: A quantative primary study to determine whether increasing source to image distance (SID), with and without the use of automatic exposure control (AEC) for antero-posterior (AP) pelvis imaging, reduces dose whilst still producing an image of diagnostic quality. Methods: Using a computed radiography (CR) system, an anthropomorphic pelvic phantom was positioned for an AP examination using the table bucky. SID was initially set at 110 cm, with tube potential set at a constant 75 kVp, with two outer chambers selected and a fine focal spot of 0.6 mm. SID was then varied from 90 cm to 140 cm with two exposures made at each 5 cm interval, one using the AEC and another with a constant 16 mAs derived from the initial exposure. Effective dose (E) and entrance surface dose (ESD) were calculated for each acquisition. Seven experienced observers blindly graded image quality using a 5-point Likert scale and 2 Alternative Forced Choice software. Signal-to-Noise Ratio (SNR) was calculated for comparison. For each acquisition, femoral head diameter was also measured for magnification indication. Results: Results demonstrated that when increasing SID from 110 cm to 140 cm, both E and ESD reduced by 3.7% and 17.3% respectively when using AEC and 50.13% and 41.79% respectively, when the constant mAs was used. No significant statistical (T-test) difference (p ¼ 0.967) between image quality was detected when increasing SID, with an intra-observer correlation of 0.77 (95% confidence level). SNR reduced slightly for both AEC (38%) and no AEC (36%) with increasing SID. Conclusion: For CR, increasing SID significantly reduces both E and ESD for AP pelvis imaging without adversely affecting image quality

    Skin Vaccination against Cervical Cancer Associated Human Papillomavirus with a Novel Micro-Projection Array in a Mouse Model

    Get PDF
    Background: Better delivery systems are needed for routinely used vaccines, to improve vaccine uptake. Many vaccines contain alum or alum based adjuvants. Here we investigate a novel dry-coated densely-packed micro-projection array skin patch (Nanopatch (TM)) as an alternate delivery system to intramuscular injection for delivering an alum adjuvanted human papillomavirus (HPV) vaccine (Gardasil (R)) commonly used as a prophylactic vaccine against cervical cancer
    corecore